Outline

Ingegneria Sismica

Ingegneria Sismica

SEISMIC DESIGN OF MULTI-STOREY CROSS LAMINATED TIMBER BUILDINGS ACCORDING TO EUROCODE 8

, Maurizio Follesa. et al “SEISMIC DESIGN OF MULTI-STOREY CROSS LAMINATED TIMBER BUILDINGS ACCORDING TO EUROCODE 8.” Ingegneria Sismica Volume 31 Issue 4: -, doi:….

Abstract

Cross Laminated Timber (CLT) structures are nowadays increasingly used worldwide and mostly in Europe where the system originated. However, in spite of this diffusion which led to the construction of a great number of multi-storey buildings all over Europe, still Eurocodes are almost completely missing provisions for CLT designers, especially regarding the seismic design. Nevertheless, Eurocode 8 requires in most cases, due to the regularity criteria being not fulfilled for most of the buildings, the use of the modal response spectrum analysis method, i.e. the linear dynamic analysis. This method requires the correct estimation of the lateral stiffness of the building in order to accurately calculate the design seismic forces in the building, which may be significantly underestimated or overestimated depending on the size of the building and the shape of the design spectrum. This can be done by modelling each connection with different methods that are often based on available test results, which are not easily accessible by a practicing engineer. This paper provides a design approach for dynamic linear modelling of CLT structures using SAP 2000. Equations are proposed based on available design codes and literature references, and used to design a 3-storey case study building. Further provisions for the seismic design of CLT buildings which are not included in Eurocode 8 are also given. Finally, the proposed design model is also compared with the results of the shaking table tests conducted in 2006 in Japan by CNR-IVALSA on a three-storey CLT building.

Related Articles

Mohamed A. Tohamy1, Mostafa M. ElSayed1, Adel. Y. Akl1
1Department of Structural Engineering, Faculty of Engineering, Cairo University, 12613 Giza, Egypt
Mehmet Yigitbas1, Ernesto Grande1, Maura Imbimbo1
1Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, 03043, Cassino FR, Italy
Yan Shi1, Xuexin Wang1, Qianzhan Cheng1, Zhao Cheng1
1School of Civil and Hydraulic Engineering, Lanzhou University of Technology, 730050 Lanzhou, China
Alper Demirci1, Semanur Kenar2
1Faculty of Engineering, Çanakkale Onsekiz Mart University, 17100, Çanakkale, Türkiye
2School of Graduate Studies, Çanakkale Onsekiz Mart University, 17100, Çanakkale, Türkiye
Guoxi Fan1, Boyuan Guo1, Peng Hu2, Shirui Sun1, Haozhe Zhang1, Lu Yu1, Xiaocheng Tang3
1College of Engineering, Ocean University of China, 266404 Qingdao, Shandong, China
2Shanghai Baoye Group Co., Ltd., 200941 Shanghai, China
3School of Civil Engineering, Jilin Jianzhu University, 130118 Changchun, Jilin, China