Outline

Ingegneria Sismica

Ingegneria Sismica

Automatic Verification Algorithm for Substation Component Position Deviations Incorporating Gaussian Distribution Registration

Author(s): Tian Lan1, Faqian Huang1, Chuanjun Peng1, Chuan Jin1, Shengyou Zou1, Jian Zhong1
1Sichuan Shuneng Electric Power Co., Ltd, Chengdu 610000, Sichuan, China
Lan, Tian. et al “Automatic Verification Algorithm for Substation Component Position Deviations Incorporating Gaussian Distribution Registration.” Ingegneria Sismica Volume 43 Issue 2: 1-22, doi:10.65102/is2026850.

Abstract

In view of the common problems such as high noise, severe structural occlusion and local density mutation in the actual collection process of substation point clouds, traditional registration methods are prone to unstable convergence and error amplification in the deviation identification task. To this end, this paper proposes an automatic verification algorithm for component position deviation that integrates Gaussian distribution registration and 3D Gaussian Splatting (3DGS). This method utilizes the Gaussian model to establish the probabilistic geometric representation of the device and constructs a continuous structural field through 3DGS, enabling the registration to maintain a stable optimization direction even in sparse and missing regions. Through the joint parameter update mechanism, the algorithm effectively suppresses the drift phenomenon of the traditional Gaussian model in irregular areas. On typical substation component data, the method proposed in this paper is compared with methods such as ICP, GMM-ICP, and CPD. The experimental results show that the deviation error of the traditional ICP is 17.2 mm, while the method proposed in this paper can reduce the deviation to 3.9 mm. The corresponding RMSE has been reduced from 11.5mm to 2.7mm. In terms of convergence efficiency, the number of iterations has decreased from 42 to 21, making the verification process more efficient. Under complex interference conditions (such as 30% noise and 50% point cloud absence), the mean deviations of the method proposed in this paper are 4.9 mm and 5.4 mm respectively, and the variance always remains around 3.5 mm², which is significantly better than the baseline model. Research shows that the Gaussian+3DGS framework has significant advantages in terms of deviation accuracy, robustness, and convergence stability, and can provide a reliable engineering solution for the automatic verification and intelligent inspection of component position deviations in substations.

Keywords
Gaussian model, 3DGS, Deviation detection, Structural reconstruction

Related Articles

Junhua Li1, Xiaojie He1, Hua Liu2
1School of Mathematics and Computer Science, Hanjiang Normal University, Shiyan, 442000, Hubei, China
2School of Mathematics and Physics, Jingchu University of Technology, Jingmen 448000, Hubei, China
Wei Guo1, Peng Tao1, Bo Ling1, Shen Hao1, Nan Kai1
1State Grid Hebei Marketing Service Center, Shijiazhuang 050000, Hebei, China
Tianzi Zheng1, Genlang Chen2, Binhua He1
1School of Computer Science and Technology (School of Artificial Intelligence), Zhejiang Sci-Tech University, Hangzhou 310018, China
2School of Computer and Data Engineering, Ningbo Tech University, Ningbo 315199, China
Jingwen Wu1
1School of Business, Minnan Normal University, Zhangzhou 363000, Fujian, China
Zijie Peng1, Qianhua Xiao2
1JiLuan College, Nanchang University, Jiangxi 330031, Nanchang, China
2College of Information Engineering, Nanchang University, Jiangxi 330031, Nanchang, China