SEISMIC ISOLATION RETROFIT OF HOSPITAL BUILDINGS WITH FOCUS ON NON-STRUCTURAL COMPONENTS

, Emanuele Gandelli. et al “SEISMIC ISOLATION RETROFIT OF HOSPITAL BUILDINGS WITH FOCUS ON NON-STRUCTURAL COMPONENTS.” Ingegneria Sismica Volume 35 Issue 4: 20-56, doi:….

Abstract

Critical facilities with high technological content like hospitals are characterized by a massive presence of earthquake-sensitive non-structural utilities and equipment whose full operation is essential in the aftermath of strong seismic events. The paper deals with several aspects of the design of seismically isolated medical centres with focus on their non-structural components. A simplified design procedure is exemplified using as case study the hospital of Lamezia Terme, located in a high seismic prone area in southern Italy, for which a seismic retrofit intervention with curved surface sliders is proposed. The preliminary sizing of the isolation system is guided by structural and non-structural targets. The protection of utilities and medical equipment requires indeed, at different seismic intensities, very stringent performance limitations, and specific thresholds are formulated to ensure both the structural integrity of the building at the ultimate states and the full operation at the service limit states. Nonlinear time-history analyses performed on the retrofitted building demonstrate the effectiveness of the procedure, by showing that, for the four design levels established by the Italian Building Code, the adopted solution provides the operation of the medical complex for frequent and occasional earthquakes and fulfils the immediate occupancy structural level for high intensity very rare earthquakes.

Related Articles

Mohamed A. Tohamy1, Mostafa M. ElSayed1, Adel. Y. Akl1
1Department of Structural Engineering, Faculty of Engineering, Cairo University, 12613 Giza, Egypt
Mehmet Yigitbas1, Ernesto Grande1, Maura Imbimbo1
1Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, 03043, Cassino FR, Italy
Yan Shi1, Xuexin Wang1, Qianzhan Cheng1, Zhao Cheng1
1School of Civil and Hydraulic Engineering, Lanzhou University of Technology, 730050 Lanzhou, China
Alper Demirci1, Semanur Kenar2
1Faculty of Engineering, Çanakkale Onsekiz Mart University, 17100, Çanakkale, Türkiye
2School of Graduate Studies, Çanakkale Onsekiz Mart University, 17100, Çanakkale, Türkiye
Guoxi Fan1, Boyuan Guo1, Peng Hu2, Shirui Sun1, Haozhe Zhang1, Lu Yu1, Xiaocheng Tang3
1College of Engineering, Ocean University of China, 266404 Qingdao, Shandong, China
2Shanghai Baoye Group Co., Ltd., 200941 Shanghai, China
3School of Civil Engineering, Jilin Jianzhu University, 130118 Changchun, Jilin, China