Outline

Ingegneria Sismica

Ingegneria Sismica

A case study of Performance Based Design according to EC8: Fixed-Base vs. Base-Isolated RC frame structures

, Donato Cancellara. and , Mario Pasquino. “A case study of Performance Based Design according to EC8: Fixed-Base vs. Base-Isolated RC frame structures.” Ingegneria Sismica Volume 27 Issue 2: -, doi:….

Abstract

The technique of the seismic base isolation (Base Isolation System − BIS) represents an innovative structural control system and, in particular, an important passive control system for seismic protection of structures. This technique has reached a high level of reliability and, as a matter of fact, isolated structures do have an elastic behaviour during the earthquakes, even of high intensity. This reliability is witnessed by the new seismic codes that allows for the use of BIS and provides specific design criteria. In this work, the Base Isolation System for a multi- storey reinforced concrete building, highly irregular in plan, has been considered. The Eurocodes (EC0; EC2; EC8) have been adopted and compared with the new Italian seismic code (NTC 2008). The base isolated structure has been compared to the fixed base structure and the significant benefits that the technique provides on the seismic response of the structure, with significant spin on the costs of the structure, have been highlighted.

Related Articles

E. Brunesi1, S. Peloso1, R. Pinho1,2, R. Nascimbene3
1EUCENTRE, European Centre for Training and Research in Earthquake Engineering Via Ferrata 1, 27100 Pavia, Italy
2Dept. of Civil Engineering and Architecture (DICAr), University of Pavia, Via Ferrata 3, Pavia 27100, Italy
3Scuola Universitaria Superiore IUSS Pavia Piazza della Vittoria 15, 27100 Pavia, Italy
R. Arvind1, M. Helen Santhi1, G. Malathi2, Huseyin Bilgin3
1School of Civil Engineering, Vellore Institute of Technology, Chennai, Tamil Nadu, India
2School of Computer Science and Engineering, Vellore Institute of Technology, Chennai, Tamil Nadu, India
3Civil (Structural) Engineering, Epoka University, Tirana / Albania
Ali Ekber Sever1, Yakup Hakan Aydin2, Pinar Usta Evci1
1Department of Civil Engineering, Isparta University of Applied Sciences, 32260 Isparta, Turkey
2Department of Mechanical Engineering, Isparta University of Applied Sciences, 32260 Isparta, Turkey
Hayri Baytan Ozmen1, Esra Ozer2
1Department of Civil Engineering, Usak University, 64200 Usak, Turkey
2Department of Civil Engineering, Tokat Gaziosmanpasa University, 60250 Tokat, Turkey
Hamid Beiraghi1, Abolfazl Riahi Nouri2
1Department of Civil Engineering, Mahdishahr Branch, Islamic Azad University, Mahdishahr, Iran
2Department of Civil Engineering, West Tehran Branch, Islamic Azad University, Tehran, Iran