Outline

Ingegneria Sismica

Ingegneria Sismica

EVALUATION OF THE EFFECTIVE PARAMETERS IN SEISMIC PERFORMANCE OF SLIT DAMPER IN BEAM-TO-COLUMN CONNECTION

, Ali Zarbi Sakrabad. and , Mohammadreza Oliaei. “EVALUATION OF THE EFFECTIVE PARAMETERS IN SEISMIC PERFORMANCE OF SLIT DAMPER IN BEAM-TO-COLUMN CONNECTION.” Ingegneria Sismica Volume 38 Issue 4: 55-69, doi:….

Abstract

During the Northridge and Kobe earthquakes, many of steel moment-resisting frames at the beam-to-column connection were damaged due to excessive deformation. As a solution, steel slit dampers were used in the connections to prevent the connections’ fracture and damage of the main members of the structure. In the present paper, a numerical investigation was carried out with ABAQUS software to investigate the parameters affecting the seismic performance of steel slit damper in beam-to-steel column connections. The damper specimen were simulated and verified with an experimental work under cyclic and monotonic loading. A reasonable agreement was obtained between the finite element analysis and the experimental test results. For easy expression of the damper performance criteria, monotonic loading were used by presenting the results in the form of moment-rotation. The variables studied included the various proposed shapes for the damper, damper boosting effect, and damper thickness in the seismic performance of beam-to-steel column connection. The results show that with increasing the thickness and strengthening of the steel slit damper, the bending moment, stiffness and energy dissipation capacity of the connection, increases. Also, the new proposed slit damper had the best performance among the other dampers.

Related Articles

Qianwen Xiong1, Yuhong Chen1
1Guangzhou University of Chinese Medicine, School of Pharmaceutical Medicine, Guangzhou,Guangdong,China,510006
Zhihao Jiang1,2, Limi Chen1,2, Jing Yang1
1Hainan Vocational University of Science and Technology, Haikou 571126, China
2Institute for Mathematical Research, Universiti Putra Malaysia, Serdang 43400, Malaysia
Limi Chen1,2, Zhihao Jiang1,2, Jing Yang1
1Hainan Vocational University of Science and Technology, Haikou 571126, China
2Institute for Mathematical Research, Universiti Putra Malaysia, Serdang 43400, Malaysia
Hui Yuan1, Minjie Chai2, Siqing Xu1, Jinsong Li1, Jinwan Zheng1
1Electric Power Research Institute, State Grid Shanxi Electric Power Co., Ltd., Taiyuan, 030001, Shanxi, China
2Jincheng Power Supply Branch, State Grid Shanxi Electric Power Co., Ltd., Jincheng, 048000, Shanxi, China
Yanhan Zhu1,2
1China Academy of Cultural Heritage, Chaoyang District, 100029, Beijing, China
2Beijing University of Civil Engineering and Architecture, Xicheng District, 100044, Beijing, China