Outline

Ingegneria Sismica

Ingegneria Sismica

Comprehensive Evaluation of Green Office Indoor Environment-Energy Efficiency Based on Data Envelopment Analysis

Author(s): Ye Zhang1, Xianlian Ning2, Wenya Li3
1GuangXi Vocational College of Safety Engineering,Nanning 530000, Guangxi, China
2Nanning Normal University, Nanning 530000, Guangxi, China
3Hebei University of Engineering, Handan 056000, Hebei,China
Zhang, Ye ., Ning, Xianlian., and Li, Wenya. “Comprehensive Evaluation of Green Office Indoor Environment-Energy Efficiency Based on Data Envelopment Analysis.” Ingegneria Sismica Volume 43 Issue 1: 1-23, doi:10.65102/is2026156.

Abstract

Manufacturing industry is a major energy consumer and a major source of environmental pollutants. Improving the green total factor efficiency of the manufacturing industry is of great significance in realizing the sustainable development of China’s manufacturing industry and the whole national economy. In this paper, a series of assessment indexes for energy efficiency are identified from the perspective of green building assessment, and data envelopment analysis (DEA) is proposed. The relative effectiveness of DMUs is evaluated by comparing the degree of their deviation from the DEA frontier surface. A basic C²R model is established according to the DEA idea, and relevant constraints are introduced to establish a BCC model for energy efficiency during the construction process. Energy efficiency analysis of office indoor environment energy consumption through the above model, the average energy efficiency of 36 green office indoor environments is 0.514 in 2018, and the average energy efficiency rises to 0.61 in 2023.In general, the energy efficiency of 36 green office indoor environments shows an upward trend during 2018-2023. At the same time, the comprehensive efficiency shows a fluctuating change of decreasing and then increasing, and the average value of the comprehensive efficiency in the three years of 2018, 2021 and 2023 is 0.369, and there is still a lot of room to improve the energy efficiency of the green industry.

Keywords
DEA; DMU; C²R model; energy efficiency; green office indoor environment

Related Articles

Zhihao Jiang1,2, Limi Chen1,2, Jing Yang1
1Hainan Vocational University of Science and Technology, Haikou 571126, China
2Institute for Mathematical Research, Universiti Putra Malaysia, Serdang 43400, Malaysia
Limi Chen1,2, Zhihao Jiang1,2, Jing Yang1
1Hainan Vocational University of Science and Technology, Haikou 571126, China
2Institute for Mathematical Research, Universiti Putra Malaysia, Serdang 43400, Malaysia
Hui Yuan1, Minjie Chai2, Siqing Xu1, Jinsong Li1, Jinwan Zheng1
1Electric Power Research Institute, State Grid Shanxi Electric Power Co., Ltd., Taiyuan, 030001, Shanxi, China
2Jincheng Power Supply Branch, State Grid Shanxi Electric Power Co., Ltd., Jincheng, 048000, Shanxi, China
Yanhan Zhu1,2
1China Academy of Cultural Heritage, Chaoyang District, 100029, Beijing, China
2Beijing University of Civil Engineering and Architecture, Xicheng District, 100044, Beijing, China
Ken Wang1, Jinhan Shu2, Kan Yuan1
1School of Digital Media, Shenzhen Polytechnic University, Shenzhen 518055, Guangdong, China
2Postdoctoral Mobile Station of Journalism and communication, Fudan University, Shanghai 200433, Shanghai, China