Outline

Ingegneria Sismica

Ingegneria Sismica

Consolidation of Soft Ground Improved by Biodegradable Prefabricated Vertical Drains with Time-Dependent Discharge-Capacity Decay: A Field-Validated Finite-Element Study

Author(s): Lewen Cheng1
1Key Laboratory of Ministry of Education for Geomechanics and Embankment Engineering, Hohai University, Nanjing 210098, China
Cheng, Lewen. “Consolidation of Soft Ground Improved by Biodegradable Prefabricated Vertical Drains with Time-Dependent Discharge-Capacity Decay: A Field-Validated Finite-Element Study.” Ingegneria Sismica Volume 43 Issue 3: 1-19, doi:10.65102/is20261303.

Abstract

Biodegradable prefabricated vertical drains (PVDs) are an emerging green alternative to conventional plastic drains, but their core material degrades during service, so the drain discharge capacity decays with time and the well-resistance effect intensifies; consolidation analyses that assume a constant discharge capacity therefore cannot reproduce the true field behaviour. Unlike previous analyses that assume an exponential or polynomial decay, this paper calibrates the discharge-capacity decay directly from laboratory tests and embeds it in a field-validated finite-element (FE) consolidation model. Laboratory accelerated-degradation and longitudinal discharge-capacity tests provided the measured decay data; after comparison with an exponential model, a logistic function with upper and lower asymptotes was selected to describe the decay, and was converted, via Darcy’s law and the equivalent-hydraulic-radius method, into a time-dependent decay function of the drain permeability. Because general-purpose FE codes cannot vary a parameter continuously in time, a staged-assignment method was proposed that discretises the continuous decay curve into successive stages and updates the drain permeability stage by stage. Using the Soft-Soil constitutive model for the non-linear compressibility of dredged silty clay, the model was validated against field settlement and excess-pore-pressure measurements at Meishan Port, Ningbo, and then applied to sensitivity analyses of the drain spacing, decay rate and decay amplitude and a 1000-day long-term prediction, providing a calibratable and field-verifiable reference for the design-parameter selection of biodegradable-PVD ground improvement.

Keywords
biodegradable prefabricated vertical drain; discharge-capacity decay; well resistance; finite element method; consolidation; parametric analysis

Related Articles

Qianwen Xiong1, Yuhong Chen1
1Guangzhou University of Chinese Medicine, School of Pharmaceutical Medicine, Guangzhou,Guangdong,China,510006
Zhihao Jiang1,2, Limi Chen1,2, Jing Yang1
1Hainan Vocational University of Science and Technology, Haikou 571126, China
2Institute for Mathematical Research, Universiti Putra Malaysia, Serdang 43400, Malaysia
Limi Chen1,2, Zhihao Jiang1,2, Jing Yang1
1Hainan Vocational University of Science and Technology, Haikou 571126, China
2Institute for Mathematical Research, Universiti Putra Malaysia, Serdang 43400, Malaysia
Hui Yuan1, Minjie Chai2, Siqing Xu1, Jinsong Li1, Jinwan Zheng1
1Electric Power Research Institute, State Grid Shanxi Electric Power Co., Ltd., Taiyuan, 030001, Shanxi, China
2Jincheng Power Supply Branch, State Grid Shanxi Electric Power Co., Ltd., Jincheng, 048000, Shanxi, China
Yanhan Zhu1,2
1China Academy of Cultural Heritage, Chaoyang District, 100029, Beijing, China
2Beijing University of Civil Engineering and Architecture, Xicheng District, 100044, Beijing, China