Outline

Ingegneria Sismica

Ingegneria Sismica

A Critical-Excitation Response Spectrum Framework for Beyond-Design-Basis Screening of Base-Isolated Nuclear Reactor Buildings

Author(s): Naser Khaji1, Ali Ahmadi1
1Civil and Environmental Engineering Program, Graduate School of Advanced Science and Engineering, Hiroshima University, 1-4-1, Kagamiyama, Higashi-Hiroshima, Hiroshima 739-8527, Japan
Khaji, Naser. and Ahmadi, Ali. “A Critical-Excitation Response Spectrum Framework for Beyond-Design-Basis Screening of Base-Isolated Nuclear Reactor Buildings.” Ingegneria Sismica Volume 43 Issue 1: 1-18, doi:10.65102/is2026002.

Abstract

This paper studies resonance-sensitive seismic demand in a base-isolated nuclear reactor building. The baseline target spectrum is the design response spectrum (DRS) defined in ASCE/SEI 43-19 for seismic design category 5 (SDC 5), which corresponds to a target performance goal of 1×10−5 mean annual frequency of exceedance. Beyond-design-basis earthquake (BDBE) levels are represented by controlled multipliers of the same DRS shape (150%, 167%, and 200%). In parallel, a critical excitation (CE) procedure is used to derive a CE-based response spectrum (CE-RS) by maximizing a selected response measure within an admissible input set constrained by physical intensity measures, including peak ground acceleration (PGA), peak ground velocity (PGV), and Arias intensity. The CE constraints are anchored using a recorded event. Response-history analyses are performed using 11 spectrum-compatible horizontal record sets. The reported outputs are peak isolation displacement, isolation-plane base shear, and peak absolute acceleration at the lumped superstructure mass as a global indicator. Results show that BDBE scaling increases demands relative to the DRS baseline, as expected. However, CE-RS produces the largest demands across all metrics, indicating that standard DRS/BDBE scaling may not fully capture resonance-driven isolation demands for long-period isolated systems. A validation check shows that CE results agree closely with CE-RS-based results (differences below about 1%). The proposed workflow provides a fast, traceable supplement for early-stage design screening and for evaluating strengthening or rehabilitation options in existing isolated systems.

Keywords
Nuclear power plants; Critical excitation method (CEM); Design-level limit; Response spectrum; Synthetic accelerograms; Beyond-design-basis earthquake (BDBE)

Related Articles

Qianwen Xiong1, Yuhong Chen1
1Guangzhou University of Chinese Medicine, School of Pharmaceutical Medicine, Guangzhou,Guangdong,China,510006
Zhihao Jiang1,2, Limi Chen1,2, Jing Yang1
1Hainan Vocational University of Science and Technology, Haikou 571126, China
2Institute for Mathematical Research, Universiti Putra Malaysia, Serdang 43400, Malaysia
Limi Chen1,2, Zhihao Jiang1,2, Jing Yang1
1Hainan Vocational University of Science and Technology, Haikou 571126, China
2Institute for Mathematical Research, Universiti Putra Malaysia, Serdang 43400, Malaysia
Hui Yuan1, Minjie Chai2, Siqing Xu1, Jinsong Li1, Jinwan Zheng1
1Electric Power Research Institute, State Grid Shanxi Electric Power Co., Ltd., Taiyuan, 030001, Shanxi, China
2Jincheng Power Supply Branch, State Grid Shanxi Electric Power Co., Ltd., Jincheng, 048000, Shanxi, China
Yanhan Zhu1,2
1China Academy of Cultural Heritage, Chaoyang District, 100029, Beijing, China
2Beijing University of Civil Engineering and Architecture, Xicheng District, 100044, Beijing, China