Outline

Ingegneria Sismica

Ingegneria Sismica

Application of a wooden dissipative panel in new buildings: parametric analysis and comparison with steel braces

Author(s): BRUNO GERMANO NOLFI1, Rosario MONTUORI2, ELIDE NASTRI3, R Coluccio, , M Peroni
1
2Dipartimento di Farmacia/DIFARMA
3Dipartimento di Ingegneria Civile/DICIV
NOLFI, BRUNO GERMANO . et al “Application of a wooden dissipative panel in new buildings: parametric analysis and comparison with steel braces.” Ingegneria Sismica Volume 40 Issue 1: 37-56, doi:….

Abstract

The purpose of the work is the evaluation of the behaviour of new wooden buildings with the installation of new dissipative wooden panels. Parametric analyses were conducted considering the use of the dissipative panel only, the system consisting of the panel coupled to an X-Lam wall and the use of steel braces. First, the sizing of the structures was carried out through a response spectrum dynamic analysis, to evaluate the conditions in which the panel could provide the best contribution. To this scope, a first parametric comparison was made considering a 9-storeys wooden building located in three sites in Italy, namely Bolzano, Fisciano and Calitri. Only for the Calitri location, which is characterized by the higher seismic intensity, the investigation was completed through a second parametric comparison which evaluated the contribution of the panel with the variation of the number of storeys with the scope of investigating if the panels are more suitable for high rise or low-rise buildings. Finally, to check the dissipative behaviour of the structural system incremental dynamic analyses (IDA) and non-linear static analyses (pushover) were executed.

Related Articles

Qianwen Xiong1, Yuhong Chen1
1Guangzhou University of Chinese Medicine, School of Pharmaceutical Medicine, Guangzhou,Guangdong,China,510006
Zhihao Jiang1,2, Limi Chen1,2, Jing Yang1
1Hainan Vocational University of Science and Technology, Haikou 571126, China
2Institute for Mathematical Research, Universiti Putra Malaysia, Serdang 43400, Malaysia
Limi Chen1,2, Zhihao Jiang1,2, Jing Yang1
1Hainan Vocational University of Science and Technology, Haikou 571126, China
2Institute for Mathematical Research, Universiti Putra Malaysia, Serdang 43400, Malaysia
Hui Yuan1, Minjie Chai2, Siqing Xu1, Jinsong Li1, Jinwan Zheng1
1Electric Power Research Institute, State Grid Shanxi Electric Power Co., Ltd., Taiyuan, 030001, Shanxi, China
2Jincheng Power Supply Branch, State Grid Shanxi Electric Power Co., Ltd., Jincheng, 048000, Shanxi, China
Yanhan Zhu1,2
1China Academy of Cultural Heritage, Chaoyang District, 100029, Beijing, China
2Beijing University of Civil Engineering and Architecture, Xicheng District, 100044, Beijing, China