Outline

Ingegneria Sismica

Ingegneria Sismica

NONLINEAR STATIC AND INCREMENTAL DYNAMIC ANALYSES FOR SEISMIC DOWN-AISLE BEHAVIOR OF RACK STRUCTURES

Author(s): Alessandro Mei1, Maurizio Orlando1, Luca Salvatori1, Paolo Spinelli1
1Department of Civil and Environmental Engineering, University of Florence, Italy
Mei, Alessandro . et al “NONLINEAR STATIC AND INCREMENTAL DYNAMIC ANALYSES FOR SEISMIC DOWN-AISLE BEHAVIOR OF RACK STRUCTURES.” Ingegneria Sismica Volume 38 Issue 2: 21-44, doi:….

Abstract

A numerical campaign comparing the seismic behavior of cold-formed steel rack structures using both Nonlinear Static Analysis (NSA) and Incremental Dynamic Analyses (IDA) is presented. A total of 140 progressively scaled natural ground-motion records, along with 2 different forces distribution for NSA, were applied to a case study model build considering geometrical nonlinearity (𝑃-𝛥 effects) and using proper elements to reproduce the pinching of beam-to-column joints in case of hogging and sagging bending moment. Data obtained from IDA were statistically processed and compared with the ones from NSA in terms of seismic vulnerability, specifically in terms of displacement demand and capacity, collapse spectral acceleration and proposing an appropriate damage index capable of tracking the state of the system as the spectral acceleration increase. Results show that NSA underestimates the displacement demand of the system and overestimates the collapse intensity measure (capacity spectral acceleration), thus not always being on the safe side.

Keywords
Cold-Formed Steel, Nonlinear Static Analysis, Incremental Dynamic Analysis, Seismic Assessment, Damage Index

Related Articles

Huiqiao Liu1
1Yinchuan University of Energy, Ningxia, 750000, China
Xin Zhao1, Yan Li1, Xiangyang Cao1, Qiushuang Li1, Jianing Zhang1
1State Grid Shandong Electric Power Company Economic and Technological Research Institute ShanDong JiNan 250001, China
Dan Yang1
1School of Marxism, Suzhou Polytechnic University, Suzhou, 215104, China
Liuhang Shen1, Xiangwen Sun1
1Ulster college at Shaanxi University of Science &Technology, Xi’an,710021, Shaanxi, China