Outline

Ingegneria Sismica

Ingegneria Sismica

Current U.S. practice of seismic qualification of suspended ceilings by means of shake table tests

, Amir S.J. Gilani. and , Shakhzod Takhirov. “Current U.S. practice of seismic qualification of suspended ceilings by means of shake table tests.” Ingegneria Sismica Volume 29 Issue 1: -, doi:….

Abstract

Suspended ceilings are among the most widely used nonstructural components. Past earthquakes have demonstrated the susceptibility of suspended ceilings to failure during seismic events. To address this vulner- ability, design codes have incorporated specific design and installation criteria for suspended ceilings. However, ceiling and grid manufacturers continue to innovate and introduce new products that are requested by engineers and architects but are not addressed in the code. Therefore, it is necessary to have the means to evaluate such prod- ucts. Because these units are difficult to analyze numerically, earthquake simulation testing can be used to assess the seismic performance of suspended ceilings. Such technique was used by one of the major manufacturers in the United States to characterize the performance of a standard code-prescribed ceiling and to use that performance as a benchmark for assessing the response of this manufacturer’s alternate installation. Testing and evaluation of data showed that the code-prescribed installation had an acceptable performance. It was also noted that the ceil- ing constructed with the proposed alternate installation performed as well as or better than the specimen installed using the code procedure. Finally, the test data revealed some of the shortcomings of the current experimental and evaluation methodology that require revisions.

Related Articles

Qianwen Xiong1, Yuhong Chen1
1Guangzhou University of Chinese Medicine, School of Pharmaceutical Medicine, Guangzhou,Guangdong,China,510006
Zhihao Jiang1,2, Limi Chen1,2, Jing Yang1
1Hainan Vocational University of Science and Technology, Haikou 571126, China
2Institute for Mathematical Research, Universiti Putra Malaysia, Serdang 43400, Malaysia
Limi Chen1,2, Zhihao Jiang1,2, Jing Yang1
1Hainan Vocational University of Science and Technology, Haikou 571126, China
2Institute for Mathematical Research, Universiti Putra Malaysia, Serdang 43400, Malaysia
Hui Yuan1, Minjie Chai2, Siqing Xu1, Jinsong Li1, Jinwan Zheng1
1Electric Power Research Institute, State Grid Shanxi Electric Power Co., Ltd., Taiyuan, 030001, Shanxi, China
2Jincheng Power Supply Branch, State Grid Shanxi Electric Power Co., Ltd., Jincheng, 048000, Shanxi, China
Yanhan Zhu1,2
1China Academy of Cultural Heritage, Chaoyang District, 100029, Beijing, China
2Beijing University of Civil Engineering and Architecture, Xicheng District, 100044, Beijing, China